Skip to main content

Table 2 The effects of XYT on ECG parameters

From: Xinyang Tablet attenuates chronic hypoxia-induced right ventricular remodeling via inhibiting cardiomyocytes apoptosis

ECG parameters

Control

Hypoxia

H+XYT

H+Cap

Heart rate (beat/min)

309.100 ± 14.410

388.700 ± 37.380

309.100 ± 12.610

343.400 ± 8.084

P Amp. (mv)

0.124 ± 0.015

0.227 ± 0.025*

0.130 ± 0.029##

0.244 ± 0.018

QTc interval (ms)

135.200 ± 5.389

241.600 ± 4.596***

202.100 ± 4.766###

217.500 ± 5.015#

QT interval (ms)

52.100 ± 2.709

98.330 ± 0.717***

91.070 ± 1.268

91.970 ± 2.772

  1. P Amp. indicated amplitude of the P wave. QTc interval indicated rate-corrected QT Interval. n = 6, *p < 0.05, *** p < 0.001 vs. control group; #p < 0.05, ##p < 0.01, ###p < 0.001 vs. hypoxia group. Statistical analyses were conducted using one-way analysis of variance (ANOVA)